Form 712 (05.13) ©SOR Inc.
1/12
The Ultrasonic Point Level Switch energizes/de-energizes
a DPDT relay to indicate liquid presence/absence within
the sensor cavity. Two piezoelectric crystals face each
other across the cavity. The transmitter crystal sends an
ultrasonic signal to the receiver crystal. When liquid fills the
cavity, the receiver crystal detects a strong signal because
liquids are good conductors of ultrasonic waves. When the
cavity is empty, the receiver crystal detects a weaker signal
because air is a poor conductor of ultrasonic waves.
701 Ultrasonic
Point Level Switch
General Instructions
Registered Quality System to ISO 9001
Design and
specifications are
subject to change
without notice.
For latest revision, go to
www.sorinc.com
NOTE: If you suspect that a product is defective, contact the
factory or the SOR
®
Representative in your area for a return
authorization number (RMA). This product should only be
installed by trained and competent personnel.
Table of Contents
PC Board Arrangement .........................2
Sensor Installation .......................... 2-3
Remote Cable Connection .................. 4-5
Electrical Connection ........................ 5-6
Failsafe Switch ..................................6
Sensor Test Procedure .........................7
Time Delay .......................................7
Installation Drawings ....................... 8-9
Dimensions .................................... 10
Troubleshooting ............................... 11
Field Replacement - PC Board .............. 11
Replacement Fuses .......................... 12
Spare Parts .................................... 12
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Point Level Switch

Form 712 (05.13) ©SOR Inc. 1/12The Ultrasonic Point Level Switch energizes/de-energizes a DPDT relay to indicate liquid presence/absence within the se

Page 2 - PC Board Arrangement

10/12Form 712 (05.13) ©SOR Inc. DimensionsIntegral model with threaded process connection shown.Process Connection *Add to Length3/4” NPT(M) Shown1” N

Page 3 - Top View

Form 712 (05.13) ©SOR Inc. 11/12Field Replacement - PC BoardIdentical replacement printed circuit boards can be ordered by specifying the part number

Page 4

12/12Form 712 (05.13) ©SOR Inc. 14685 West 105th Street, Lenexa, KS 66215  913-888-2630  800-676-6794 USA  Fax 913-888-0767Registered Quality

Page 5

2/12Form 712 (05.13) ©SOR Inc. PC Board ArrangementSensor Installation (Applies to all models)Series 701 Ultrasonic Level Sensors can be mounted by i

Page 6 - Nine-Position Terminal Strip

Form 712 (05.13) ©SOR Inc. 3/12Horizontal MountingWhen tightened securely, the sensor cavity must be positioned vertically for optimum drainage when p

Page 7 - Form 712 (05.13) ©SOR Inc

4/12Form 712 (05.13) ©SOR Inc. Control Board (See Page 2)Electronics HousingConduit Must Meet Class 1 Group C & D;Class II Groups E, F & G;Div

Page 8 - Installation Drawings

Form 712 (05.13) ©SOR Inc. 5/12Electrical Connection (Applies to all models)Sensor Connections Inside Sensor BaseInside the sensor base, a remote inte

Page 9

6/12Form 712 (05.13) ©SOR Inc. B. Line Power TerminalsTerminals are provided for incoming power leads on the nine-position PC board terminal strip.Sup

Page 10 - Dimensions

Form 712 (05.13) ©SOR Inc. 7/12Sensor Test Procedure (Applies to all models) Disconnect a sensor cable from the PC board. Measure capacitance across

Page 11 - Troubleshooting

8/12Form 712 (05.13) ©SOR Inc. Installation DrawingsCSA Probe/Electronics Combinations

Page 12 - Spare Parts

Form 712 (05.13) ©SOR Inc. 9/12Installation DrawingsFM Probe/Electronics Combinations