Sor 1530 Pneumatic Level Switch Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Sor 1530 Pneumatic Level Switch. SOR 1530 Pneumatic Level Switch User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Form 439 (04.13) ©SOR Inc.
1/4
The side mounted SOR
®
1530 Pneumatic Level Switch provides a pneumatic output signal
for either a high or low level condition.
1530 Side Mounted
Pneumatic Level Switch
General Instructions
Registered Quality System to ISO 9001
NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative
in your area for a return authorization number (RMA). This product should only be installed by
trained and competent personnel.
Design and specifications are subject to change without notice.
For latest revision, go to www.sorinc.com
e
u
m
a
t
i
c Level Switch provides a pneumatic output si
g
o
l
e
v
e
l
condition.
e
l
S
w
General Instruc
t
i
The float moves a magnet into the field of a magnetically actuated pneumatic valve. The
pneumatic valve is pilot operated. An amplifying relay provides quick response.
The unit may be mounted for either high or low liquid level alarm by rotating the switch
body. Wrench flats provide ease of rotation.
High Level Pneumatic Output Signal (Direct Acting) Install with pneumatic connections
on the upper side of the body when the unit is tightened into the vessel.
Rising liquid level raises the float upward causing the float stem magnet to repel the
actuating lever magnet and seal the pilot nozzle. Resultant pilot pressure build-up triggers
the amplifying relay to pass pneumatic signal through the output port.
Low Level Pneumatic Output Signal (Reverse Acting) Install with pneumatic connections
on the lower side of the body when the unit is tightened into the vessel.
Falling liquid level lowers the float downward causing the float stem magnet to repel the
actuating lever magnet and seal the pilot nozzle. Resultant pilot pressure build-up
triggers the amplifying relay to pass pneumatic signal through the output port.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 1530 Side Mounted

Form 439 (04.13) ©SOR Inc. 1/4The side mounted SOR® 1530 Pneumatic Level Switch provides a pneumatic output signal for either a high or low level cond

Page 2 - Float Attachment

2/4Form 439 (04.13) ©SOR Inc. Before Installing the Level Switch Inspect the unit for any shipment damage. Check for mechanical clearance. The float

Page 3 - Dimensions

Form 439 (04.13) ©SOR Inc. 3/4Linear = mm/inchesDrawing 0390026Dimensions35.61.40MAX59.82.35FLOATTRAVEL78.6 REF3.10168.36.6360.32.3898.43.88PROCESSCON

Page 4 - Troubleshooting

4/4Form 439 (04.13) ©SOR Inc. Replacement Parts14685 West 105th Street, Lenexa, KS 66215  913-888-2630  800-676-6794 USA  Fax 913-888-0767Reg

Commentaires sur ces manuels

Pas de commentaire