Form 416 (01.13) ©SOR Inc.
For ATEX Certi ed Models
Maximum Surface Temperature
T6 Rating - 85
o
C
T5 Rating - 100
o
C
Operation
Designator
Adjustable Range
(Increasing Temperature)
Overrange Temperature
Maximum Process
Pressure
°F °C °F °C psi bar
135 -50 to 70 -45 to 21 190 88 2300 158
125 40 to 225 5 to 107 360 182 2300 158
115 150 to 375 66 to 190 520 270 2300 158
105 300 to 1000 150 to 540 1100 590 1000 70
Designator AC Rating DC Rating (Resistive)
SPDT DPDT Volts Amps Volts Amps Volts Amps
K KK 250 15 - - - -
KA N/A 125 1 - - - -
J JJ 125 1 - - 30 1
G GG 250 15 125 0.5 - -
A AA 250 11 - - 30 5.0
L LL 250 15 125 0.5 - -
E EE 250 5 - - - -
C N/A 250 15 125 0.5 - -
S N/A 125 10 125
1.5 Min.
10.0 Max.
--
B BB 250 5 125 0.3 - -
Y VY 250 5 - - - -
W N/A 250 5 125 0.3 - -
T N/A 250 15 - - - -
H N/A 250 15 - - - -
N/A EB 250 11 - - - -
AF AG 250 5 - - 30 5
EFEG1251----
JF JG 250 7 250 .25 30 1
Vue de la page 5
1 2 3 4 5 6 7 8

Commentaires sur ces manuels